Roof Underlayment Overlap
Video of the day.
Roof underlayment overlap. Synthetic roofing underlayment is to be laid horizontally parallel to eave with printed anti slip side up starting at the bottom of the lowest roof eave with a 1 5 underlayment overhang at the eave covering the pre installed eave drip edge. You can see the difference between the underlayment overlapped 19 inches on the roof to the right and overlapped 2 inches on the roof to the left. Continue along the roof to the other end and trim the felt flush at the end with a utility knife. Is roofing felt required.
In steep slope roofs 4 12 and steeper the upper courses of felt underlayment should overlap lower courses by at least 2 inches. The overlapping felt creates a secondary barrier for moisture and wicks water away from the shingles above and the sheathing below. Overhang the roof rake edge 1 5 and cover the underlayment with a metal rake edge trim. Subscribe and share please.
By comparison the standard overlap for single ply underlayment is only 2 inches at horizontal laps and 4 inches at vertical laps. Two ply roofing underlayment typically overlaps by half the width of the roll plus one inch for headlap. Therefore a 2 inch overlap provides redundancy at the edges where the barrier is weakest. Overlap the end of a roll about 4 inches with the start of a new roll and fasten both pieces to the.
I want to be. Roofing felt is required to overlap 2 inches over the lower felt course. The headlap is narrow band of 3 ply coverage at the top of each lap as shown in the illustration. This article series discusses roofing felt specifically addressing the roofing code or roofing manufacturer s requirements for use of an underlayment such as roofing felt tarpaper or other underlayment products beneath asphalt shingles and other.
Most roofing underlayments are 36 in. Here is a video about roofing underlayment. Wide the material needs to be overlapped a minimum of 19 in to achieve full double coverage. Residential and commercial roofing shingles slate roof ventilation roof underlayments asphaltic and tpo roof membranes.
Minimum overlap guidelines are set by the manufacturer. Felt details for various roof slopes amp. That s half the width of the roll plus one inch for headlap. Some contractors prefer the back roll method.
How to install roofing underlayment the proper way. Roofing shingles and materials plus factory certified roofers including ratings from real homeowners from north america s largest roofing manufacturer. Roofing underlayment roofing felt requirements.