Roof Rafter Span Tables Australia
Can t find what you are looking for.
Roof rafter span tables australia. Posts these span tables are designed for a minimum post size of 50 x 50 x 2 5mm up to a maximum height of 3 0m. Use recommended minimum roof pitches as specified by roof sheet supplier. Table assumes a maximum flooring mass of 40kg m2. Maximum span of lintel mm tile roof 240 x 35 2600 2100 1000.
2 for design parameters refer to figure 7 26. Reading off the empty under table with h 5m hc 2 5m span table c will be used to determine the spans. Visit the roof framing page for more information on cutting roof rafters and visit the roof pitch calculator for determining rafter lengths based on rise and run. Flat roof span tables allow for a maximum roof pitch of 5ยบ.
Pitching beams 23. Pergola rafter spans for 600 mm and 900 mm spacing. Roof beams 20 verandah beams 22 garage roof. Use the single span tables for the purpose of obtaining the appropriate size.
Our experienced support team can assist with enquiries ranging from beam sizing to installation advice. Tables such as those for rafters floor joists and ceiling joists require the spacing of members to be known. Rafter or uss spacing w lintel span sheet roofing tiled roofing roof load width rlw mm. For simple construction such as domestic construction this can be determined from span table supplements in as1684 2 and as1684 3.
Spantec has prepared these tables for use by people skilled in the design and specification of the type of. Rafter spans for southern yellow pine douglas fir and eastern spruce. A maximum roof pitch of 25 degrees is assumed. Span tables allow users to choose an appropriate size and stress grade to achieve spanning needs.
Technical diagram span tables f7 rafters on page 35 30mm m aximum allow able sp ans mm sheet roof spacing mm rafter size 600 760 900 1000 1200 66 x 30 1250 1150 1050 1000 950 90 x 30 1650 1550 1550 1400 1300 138 x 30 2600 2300 2150 2000 1800 185 x 30 3000 2650 2450 2350 2150 230 x 30 3050. Or selected in order to obtain the. Step 4 assume the wind classification for the area is n1 and the roofing profile is stramit corrugated cladding 0 48mm bmt thickness in a single span configuration. 1 refer to general notes for information that is relevant for all span tables.
Wind classification n1 n2. From span table c the maximum allowable single span is 2160mm. Stress grades and timber sizes combine to determine the spanning ability of load carrying members. Rafter span tables use these tables to determine lengths sizes and spacing of rafters based on a variety of factors such as species load grade spacing and pitch.
Joists crippled over supports shall be considered as single span joists. This is set by the roof use you selected in the previous screen and cannot be modified. Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.