Roof Leader Line
It is connected to the mainline with a swivel or line to line connection such as the double uni knot.
Roof leader line. This reveals that the minimum size for the leader pipe is 5. 300 x 500 150 000 sq. This drain is found on the roof and it connects the roof to an outlet pipe. Buried or underground roof drainage downspout defects clogging overflowing holes corrosion leaks that cause wet basements or crawl areas proper installation of buried downspout extensions proper installation of french drains seepage pits at flat sites gutter downspout defects cause wet basements crawl areas questions answers about installing maintaining repairing buried roof.
A trap for a leader line or area drain can be present either inside of outside the building. When sizing roof drains the limiting factor for the amount of water each drain will carry away is the size of leader therefore increasing leader size decreases the number of drains required. The water is directed away from the building s foundation to protect the foundations from water damage. Otherwise sewer gas will escape between the roof leader line and where it enters the underground drain.
The leader line can be a variety of materials including a fluorocarbon line nylon monofilament line multi strand cable single strand wire braided line or even. In addition to their ornamental appeal he points out that leader heads. But this isn t the whole story. This table is based on zurn s roof drain vertical requirement for horizontal roof areas at various rainfall rates table.
A downspout waterspout downpipe drain spout roof drain pipe leader is a pipe for carrying rainwater from a rain gutter. The first step in sizing a roof drain is to calculate the surface area of the roof that the drains will be covering as well as the average hourly rainfall rate at the building location. Downspouts are usually vertical and usually extend down to ground level. Roof area is 300 x 500 ft.
Calculate drains needed. A leader line is the last 3 20 feet of line that is connected to a hook or lure. Step by step sizing of zurn drains step 1. If outside roof leader lines connect to your combined house sewer outside your house the combining point each leader line drain must be trapped.
The result is the number of drains needed. The top portion of the drain has a strainer or a cover which prevents leaves and other debris from entering the drain to some extent. The waste accumulated around the strainer would lead to block in the drainage of water. Calculate total roof area.
The above sizing data is offered as a guide only. Take the roof s total square footage and divide by the total square footage handled by one drain. The next step is to determine each roof area that will be served by a separate leader drain pipe scupper or downspout.