Roof Hatch Code Requirements
When a hatch is left in the open position personnel working atop a roof can lose their footing trip over the hatch s curb or even step backward into the areaway without looking thereby sustaining debilitating or even fatal injuries.
Roof hatch code requirements. The distance from the center line of rungs or cleats to the edge of the hatch opening on the climbing side shall be not less than 24 inches for offset wells or 30 inches for straight wells. Ladders shall have rung spacing not to exceed 12 inches 305 mm on center. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. The ontario building code regulations state that an attic space that is higher than 600 mm must have access from the floor immediately below by either a safe stairway or by a hatch no smaller than 550 mm by 900 mm.
All open roof hatches regardless of size or number of covers can present fall hazards. In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5m2 in area and having a minimum dimension of 2 feet 610 mm. 7 all hatch covers shall open a minimum of 60 degrees from the horizontal. The uppermost rung shall be a maximum of.
Where a stairway is provided to a roof access to the roof shall be provided through a penthouse complying with section 1510 2 of the california building code. Bilco roof hatches provide safe and convenient access to roof areas by means of an interior ladder ship stair or service stair. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m 2 in area and having a minimum dimension of 2 feet 610 mm.
Where a stairway is provided to a roof access to the roof shall be provided through a penthouse complying with section 1509 2. A variety of special sizes are also available to provide an accessible way to install or remove large pieces of equipment from a building. The side railing shall extend above the parapet or roof edge not less than 42 inches 1067 mm. Guard shall be provided where the roof hatch opening is located within 10 feet 3 05m of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 76 2cm above the floor roof or grade below.