Roof Fastener Pull Tester
It is designed to record and document on site pull out values.
Roof fastener pull tester. We are there when you need us so give us a call today. Do you already have a competitor s pull tester and need calibration or repair services. Our pull testers are commonly used by the roofing and construction industries to evaluate. This dedicated kit comes with a full range of accessories.
Anchors and fasteners spray foam vapor barriers other general pull out and adhesion tests. Digital 4 000 lbs pull tester for screws anchors bolds full set of accessories for testing fasteners display peak force digital version. The pull force required is typically determined prior to the test. We do that too.
The extractor fastener tester is an essential tool in building industries where it is important to validate and check for faulty fixing anchors on both new and old construction. It is used to prove the fastening integrity for existing or new roof construction. Pull out strengths for these decks are quite low typically about 40 pounds withdrawal compared to several hundred pounds per fastener in steel wood and concrete. It can be used in horizontal or vertical tests in all type of substrates.
Fastener spacing density is increased to compensate for the low pull out. From an analog pull tester to a digital force gauge andilog has the force testing equipment you require. Grips and lifter feet we offer a wide variety of grips and attachements designed to be sued with our digital and anlog pull testers for most standard and lighweight fasteners used today. If the fastener meets the required pressures then its use with that deck type is approved.
A pull tester with its calibrated digital gauge 5 kn or 10 kn. The tester is then used to pull the fastener out of the deck. The force necessary to pull the fastener out of the deck is recorded. Trufast follows the ansi spri fx 1 standard for performing and reporting the results of pull out tests.
Omg supplies roofing fasteners for the roofing industry as well as pipe supports insulation adhesives retrofit roof drains and construction accessories. A pullout test is performed by driving a fastener into the deck and leaving enough room to attach the pullout tester to the fastener head. A detailed report will be provided following recording analysis and review of the accumulated job site data. Com ten s roofirst pull tester is a valuable solution to test fasteners on the roof.
It is designed to record and document on site pull out values. Screws ntb rawl tyle. Ansi spri fx 1 american national standard field test procedure for determining the withdrawal resistance of roofing fasteners pdf.