Roof Drain Pipe Design
Hy tech is an authorized distributor of all roof drain manufacturers so you can find what you need when you need it.
Roof drain pipe design. Section 101 5 of the ipc tells us not to reduce the pipe size in the direction of flow. Or 12 drains required. This reveals that the minimum size for the leader pipe is 5. Horizontal drain 10 000 sq ft.
Buried or underground roof drainage downspout defects clogging overflowing holes corrosion leaks that cause wet basements or crawl areas proper installation of buried downspout extensions proper installation of french drains seepage pits at flat sites gutter downspout defects cause wet basements crawl areas questions answers about installing maintaining repairing buried roof. The flow rate used for sizing the storm drainage piping shall be based on the maximum anticipated ponding on the roof. Watts drainage products rd 300 r series 4 in. We also stock many of the top selling drains and parts onsite so most orders ship same day.
Enter table 1108 2 until you find a diameter pipe that will. Rd rd 10 000 4 x 3 75 9 375 sq ft. But this isn t the whole story. The published roof drain flow rate based on the head of water above the roof drain shall be used to size the storm drain drainage system in accordance with section 1106.
Different horizontal sloping will offer different drainage capacities. According to the chart for 1 8 slope per 12 of pipe for 5 000 square feet of roof area with a 6 per hour of rainfall the required pipe size is 8. To size the vertical roof drain for the same parameters 5 000 square feet of room area and 6 per hour of rain consult table 1106 2 figure 3. Take the roof s total square footage and divide by the total square footage handled by one drain.
Code tables outline pipe slopes of. If you need help finding a drain ask our drain wizard or call to speak with our roof drain expert. Use this downspout extension to divert water away from the foundation or connect to drainage pipe and catch basin to control drainage. 50 000 4 400 11 36.
The result is the number of drains needed. The roof drainage outlets and rainwater downpipes are calculated based on the design principles for gravity drainage systems established in ss525 2006 code of practice for drainage of roofs. To convert to an area for use in table 1108 2 do this. The calculations below are meant for drainage from flat roofs where water are expected to spread over the entire flat roof during rain.
Pipe sizing is listed as amount of square foot roof areas served by the drains. A minimum 5 inch diameter drain on a 1 4 inch per foot slope is required. Section 1105 roof drains 1105 2 roof drain flow rate. 1 8 1 4 and 1 2 per foot.